April 1996 Engineering Notices

Engineering Notices

Plans Serial #196 and below:

Drawing #11 - Aileron push rod length should be changed from 7 3/4" to 8 1/4".

Drawing #12 -Flap push rod length should be changed from 6.0" to 6 3/4".

NOTE:

Be sure to use 2024 T3 or 2024 T4 aluminum for the 1/8" X 1 1/4" main spar cap strips as shown on drawing #3 (See Material Box).